Calibration and verification support for ISO 80369 test setups

Plan service for reference connectors, gauges, fixtures and connector test equipment with the right certificate wording, measured feature, method context and periodic recalibration plan.

KingPo ISO 80369, ISO 5356 and ISO 18250-3 medical connector test equipment calibration service
Traceable service support

Scope, product identity, measured parameter and documentation are confirmed before service starts.

Overview

Separate calibration, dimensional verification and functional verification

ISO 80369 test capability often combines mechanical reference parts, gauges, fixtures and instruments. The service scope should match the product type and the customer document requirement.

Reference connectors

Identity, dimensional characteristics, mating interface context and document requirements for ISO 80369 connector verification setups.

Gauges and gauge sets

Plug gauges, ring gauges, Luer gauges and grouped gauge sets used for dimensional verification and routine inspection planning.

Test equipment

Leakage, subatmospheric air leakage, force, torque and conditioning equipment with calibration or functional verification planning.

Fixtures and accessories

Holding, alignment, assembly and method-specific accessories reviewed with the instrument and connector application.

What we calibrate

Products used around connector verification benches

Calibration planning may involve new product orders, returned instruments, reusable gauges or a full connector verification setup. KingPo helps define the service scope before quotation.

Metrology bench scene for medical connector gauge calibration planning
Measurement capabilities

Review the measurement methods available for your product

KingPo supports dimensional and surface inspection for connector gauges, reference connectors, fixtures and related test tools. The applicable method and document scope are confirmed for the selected product.

KingPo CMM inspection for ISO 80369 medical connector gauges and reference connectorsInspection scope

CMM dimensional inspection

Coordinate measurement support for connector gauges, reference connectors and precision fixtures where dimensional evidence is part of the service discussion.

KingPo thread scanning inspection for ISO 80369 Luer lock reference connectorsInspection scope

Thread scanning

Thread profile, pitch, flank and lock-interface inspection context for Luer lock reference connector and gauge discussions.

KingPo surface roughness testing for ISO 80369 Luer gauges and reference connectorsInspection scope

Surface roughness review

Surface finish review for critical mating, sealing or gauge surfaces before document scope and certificate wording are confirmed.

KingPo height gauge measurement for medical connector calibration toolsInspection scope

Height and vision measurement

Height gauge and non-contact vision measurement support for vertical dimensions, profiles, edges, diameters, angles and connector features.

Service options

Choose the service that matches the result you require

Tell us what must be measured or verified and which document you need. We will confirm whether the work is calibration, dimensional inspection, functional verification or recalibration support.

Calibration planning

Define the product item, measured parameter, standard context, acceptance document and due-date requirement before quotation.

Dimensional verification

Support gauge and reference connector dimensional checks where the request depends on the feature, drawing and certificate wording.

Functional verification

Confirm that leakage, force, torque or fixture behavior should be checked as a functional test rather than a dimensional certificate.

Recalibration support

Plan periodic service intervals, document renewal and returned-product handling for equipment and reusable verification tools.

Product type calibration

Match the product type to the document need

Reference connectorFigure, standard, connector side, drawing or product code - Dimensional verification and identity documentation
Gauge or gauge setGauge type, measured feature, tolerance basis and quantity - Calibration or dimensional verification certificate
Leakage testerPressure or vacuum channel, range and test method context - Instrument calibration and functional verification
Force or torque equipmentRange, fixture interface and test method - Instrument calibration and setup verification
Fixture or assembly toolCompatible connector, equipment and setup role - Fit, function or documentation review
Documents

Prepare these details before requesting service

  • Product model or drawing reference
  • Serial number if already supplied
  • Applicable ISO 80369 part or test method
  • Measured feature, pressure, force or torque range
  • Required certificate wording
  • Requested due date and shipping location
Traceability and accredited options

Certificate scope is confirmed before quotation

KingPo can support inspection and verification documentation for applicable products. Third-party accredited certificate submission can be coordinated where required, but accredited availability depends on the selected laboratory, the requested measurement item and that laboratory's approved scope.

Discuss Calibration Scope
Certificate boundary

Use the right certificate wording in the inquiry

The page does not claim that every activity is covered by KingPo-owned accreditation. Buyers should state whether they need in-house inspection, functional review or third-party accredited certificate support.

KingPo in-house inspection and condition review

Useful when the buyer needs dimensional review, maintenance assessment, product identity support or a quotation-stage inspection record before shipment or service.

Third-party accredited laboratory submission

Used when the customer requires an accredited certificate. Availability depends on the selected laboratory, measurement item and approved scope.

Request-only controlled documents

Datasheets, full manuals, drawing packages, report samples and certificate examples are matched to product scope rather than published as generic downloads.

Process

From service request to updated documents

01Identify product and scope
02Confirm calibration or verification need
03Prepare quotation and schedule
04Receive product or build new order
05Perform service and documentation
06Return documents and next interval guidance
Periodic recalibration

Keep connector verification equipment ready for repeat use

For reusable gauges, test instruments and lab setups, periodic recalibration planning helps keep documents current and reduces last-minute service delays before audits or production checks.

Share the current certificate, product serial number, service interval expectation and required return date when requesting recalibration.

Third-party accredited test report sample for medical connector test equipment
FAQ

Calibration request questions

Is every product handled through the same calibration process?

No. Reference connectors, gauges, fixtures and instruments can require different checks, documents and service wording.

Can KingPo coordinate ISO/IEC 17025 accredited calibration?

Third-party accredited calibration can be coordinated where required, subject to confirmed scope and availability.

When should I ask for verification instead of calibration?

Use verification when the request is about confirming setup behavior, fit, function or application readiness rather than calibrating a measured instrument or gauge.

Can calibration be requested with a new product order?

Yes. Include the document and certificate expectation in the RFQ so it can be planned with the product, lead time and shipment.

Request calibration

Send product details and certificate expectations

Include the product model, serial number if available, method context, certificate requirement, service deadline and whether third-party accredited calibration needs to be coordinated.